Under Review2026
Contrastive pretraining across EEG datasets, and why it failed
IEEE Transactions on Biomedical Engineering (TBME)
First and corresponding author
A large apparent gain from pretraining on five datasets disappeared under a matched control — the datasets were still separable by recording site after alignment, meaning the model had learned which laboratory the data came from rather than anything about the signal. Fixed with a label-free alignment step that adds no parameters and no inference cost, taking held-out accuracy from 67% to 75%. Moving augmentation onto the GPU cut a pretraining run from around twenty hours to five.
Contrastive LearningEEGDomain AdaptationNegative Result